IFBD-HE0708 BE07 Users Manual
3-25
3.1.8.3. F/W Update
LogintothisproductusingFTPtoupdatetheNICrmware(F/W)byuploadingtheversionupgradebinarydatatothe\rmware\
directory.
When uploading F/W data, the FTP server calculates the CRC value of the F/W data and checks that it has
beentransferredcorrectly.Ifthermwareisnotcorrectlytransferred,canceltheupload.
Whenalldatahasbeenconrmedtobecorrectlyreceived,startwritingtotheFlashROM.Ifwritingtothe
Flash ROM ends normally, the printer will automatically be reset.
Writingtakesseveralminutes.Absolutelyneverturnoffthepowerorapplyaresetpriortonalresetbeing
applied. If terminated partway, the Flash ROM data will be damanged, and later it may not start up.
The following describes the procedures to update the F/W of this product using FTP.
For Windows, start the command prompt, then following the directions below. For UNIX/Linux, do the same opera-
tions on the shell execution screen.
(Assumed Conditions) Printer IP address = 192.168.10.1
Assumes the main F/W data (”HE7_V100(NIC_MAIN).bin”) for the for this product is in the current directory D:/
when FTP is executed on the computer.
←ConnecttoFTP
←Entertheusername
←Movetothermwaredirectory
←Enterthepassword(Default:public)
←Currentdirectorypositiondisplay
←Specifybinarytransfermode
←Writethermwarele
←Waitherefortheprintertorestart
←QuitFTP