13.4 Sensor Adjustment Mode
13.4.1 Adjusting the Paper Out/Black Mark Dual Use Sensor
Adjusting Procedures:
A. Set the DIPSW to enable the sensor adjustment mode.
B. Press the FEED switch while turning on the power.
C. With paper set, turn the VR2 to adjust to the position where the POWER/ERROR both light.
If the adjustment point is not found, the adjustment is not possible.
Turn the power off. Set the DIPSW to disable the sensor adjustment mode.