While in Maintenance Mode, the following information can be accessed and/or modied:
SW versions - The latest software version loaded in the system. The abbreviation of the versions are as follows:
- G = GUI (Graphical User Interface) Software version
- CV = Cardio Vascular Software version
- FT = FIT CPU Software version
- CCB = CCB (Center Control Board) Software version
- xCB = Translator Board Software version on Treadmills; LCB Software version on Bikes/TBT/Stepper
Serial Number - The last ve digits of the display serial number.
Model - The product type (treadmill, bike, etc.).
Units - The units of measurement (English or Metric).
Language - The language that the messages are displayed in.
Max Time - The maximum time allowed for a single workout.
Weight - The default user weight used for Quick Start programs.
Oper Hours - The cumulative amount of usage hours.
Dist Logged - The cumulative distance logged.
METs Display - Allows the manager/owner to select the METs Availability (ON or OFF).
Pause Time - Allows the manager/owner to select the length of the pause (30, 45, 60, 90, or 120 seconds).
Auto Fan - Allows the manager/owner to select the Auto Fans Functionality (ON or OFF).
Lock Out - Allows the manager/owner to select the Lock Out Function (ON or OFF).
Lock Out ID - Allows manager/owner to set a password for the Lock Out feature.
Max Speed - English (From 5.0 to 15.0) or Metric (From 5.0 to 24.1).
Accel Time - Allows the manager/owner to set the AccelerationTime of treadmill (From 25 to 60 seconds).
Decel Time - Allows the manager/owner to set the DecelerationTime of treadmill (From 20 to 60 seconds).
Club ID - Allows the manager/owner to set a Club ID.