INSSTCNP15MA0914
7
First Start-up
At the rst start-up, the thermostat is initially in the Day and
modes. The temperature is displayed in degrees Celsius
and the standard factory set point adjustment is 25°C. The
maximum oor temperature is limited to 28°C.
Maximum floor temperature limitation
At any time, the oor temperature (both in and modes)
is maintained at less than 28°C (82°F) in order to avoid
overheating caused by an excessive heating request, which
could damage some materials or be detrimental for health.
Temperature set points
The gures beside the icon indicate the temperature set
TESTA/F
Single
programming
mode
Security mode
Night mode
Day mode
Red Indicator
(EGFPD Test)
EGFPD button
Ambient
temperature
(Ambient mode)
Floor
temperature
(Floor mode)
OPERATION