www.stiebel-eltron.com DCE 11/13 | 25
INSTALLATION
Installation
Appliance installation when replacing an appliance
When replacing an appliance, you can re-use the upper mounting
holes of commonly available small water heaters.
140
43258
D0000045070
1
2
1 Upper mounting holes
2 Lower mounting hole
Using a screwdriver and working from behind, break out the
upper marked anchorage points in the back panel.
Position the mounting template over the existing drill holes.
Mark out the lower mounting hole.
Drill the lower mounting hole. Use an appropriate rawl plug.
Insert the upper screws. Align the appliance horizontally. In-
sert the lower screw.
Firmly tighten all screws.
Water connection
!
Material losses
The filter must be built into the cold water inlet for the
appliance to function correctly.
Tap installation
Install the tap. For this, also observe the tap operating and
installation instructions.
!
Material losses
When making the connections, counter the torque
on the appliance using an appropriate spanner.
For pressurised connection of the appliance only:
Note
Fit the 3/8 connection hose provided and the 3/8 tee.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
Ensure that the appliance is earthed.
Ensure the appliance can be separated from the power
supply by an isolator that disconnects all poles with at
least 3mm contact separation.
WARNING Electrocution
In the delivered condition, these appliances are equipped
with a power cable.
Connection to a permanent power supply is possible,
provided the cross-section of the fixed cable is at least
equal to that of the standard power cable for the ap-
pliance. A maximum cross-section of 4x6mm² may be
used.
!
Material losses
Observe the type plate. The specified voltage must match
the mains voltage.
Connect the power cable in accordance with the electrical
connection diagram (see chapter "Installation/ Specifica-
tion/ Wiring diagram").
Adjustable connected load
You can choose from 2 connected load stages. The high load is
preset. If you wish to select a different load, please follow the
steps below.
13kW
11kW
D0000039993
Plug in the coding card in accordance with the selected con-
nected load.
Change the type plate. Tick the selected connected load.
Please use a ballpoint pen to do this.