30 |DCE 11/13 www.stiebel-eltron.com
INSTALLATION
Specication
15. Specification
15.1 Dimensions and connections
293
100
188
85
99
35
19
b02
b03
c01
c06
203
301
D0000039746
b02 Entry electrical cablesI
b03 Entry electrical cablesII
c01 Cold water Inlet Male thread G 3/8A
c06 DHW outlet Male thread G 3/8A
15.2 Wiring diagram
3/PE ~ 380-415 V
D0000040233
3
4
1
2
1 High limit safety cut-out
2 electronic safety switch
3 Electronic
4 Heating system
!
Material losses
In the case of a permanent power supply, connect
the power cable according to the terminal designa-
tion of the socket terminal.
15.3 Application areas / conversion table
Specific electrical resistance and specific electrical conductivity
(see chapter "Installation/ Specification/ Data table").
Standard specification
at 15 °C
20°C
25°C
Spec. re-
sistance
ρ ≥
Spec. conduc-
tivity σ ≤
Spec. re-
sistance
ρ ≥
Spec. conduc-
tivity σ ≤
Spec. re-
sistance
ρ ≥
Spec. conduc-
tivity σ ≤
Ωcm mS/m μS/cm Ωcm mS/m μS/cm Ωcm mS/m μS/cm
900 111 1111 800 125 1250 735 136 1361
1000 100 1000 890 112 1124 815 123 1227
1100 91 909 970 103 1031 895 112 1117
1200 83 833 1070 93 935 985 102 1015
1300 77 769 1175 85 851 1072 93 933
Outlet temperature approx. 60°C for the kitchen sink and
when using a thermostatic valve
Outlet volume
Appliance kW 11 13.5
Cold water inlet temperature
6°C l/min 2.9 3.6
10°C l/min 3.2 3.9
14°C l/min 3.4 4.2
Ideal temperature of approx. 38°C for handwashing etc.
Amount of mixed water
Appliance kW 11 13.5
Cold water inlet temperature
6°C l/min 5.0 6.1
10°C l/min 5.7 6.9
14°C l/min 6.6 8.1
Values in the table are relative to a rated voltage of 400 V. The
mixed water volume and outlet volume are subject to the available
supply pressure and the available mains voltage.
15.4 Pressure drop
Taps/valves
Pressure drop at flow rate 10 l/min
Mono lever mixer tap, approx. MPa 0.04 - 0.08
Thermostatic valve, approx. MPa 0.03 - 0.05
Hand shower, approx. MPa 0.03 - 0.15
Sizing the pipework
When calculating the size of the pipework, a pressure drop for the
appliance of 0.1MPa should be taken into account.
15.5 Fault conditions
In case of faults, loads up to a maximum of 80 °C at a pressure of
1.0MPa can occur temporarily in the installation.
15.6 Country-specific approvals and certifications
Test symbols can be seen on the type plate.