24 |DCE 11/13 www.stiebel-eltron.com
INSTALLATION
Installation
Pressure-tested, with pressure-tested tap
850
520 - 570
≈ 600
≥80
≥ 70
D0000039997
9.1.2 Undersink installation for washbasin
Non-pressurised, with non-pressurised tap
850
520-570
≈ 600
≥ 80
≥ 70
D0000040000
Pressure-tested, with pressure-tested tap
850
520 - 570
≈ 600
≥ 70
≥ 80
D0000039999
10. Installation
10.1 Standard installation
- Electrical connection to upper part of appliance
For further connection options, see chapter "Installation/ Instal-
lation/ Installation alternatives".
Appliance installation
Note
Mount the appliance on a wall.
The wall must have a sufficient load-bearing capacity.
D0000039991
Undo the snap fastener between the water connectors using
a screwdriver.
Remove the appliance front cover by pulling it forwards.
5,5 - 6,5
13
2
D0000039992
1 Fixing screws
2 Alignment rib
3 Optional fixing points
Mark the location of the 2 drill holes on the centre axis using
the enclosed installation template (to be found at the back of
this instruction booklet).
Drill the holes. Use suitable rawl plugs and screws. Use
round head or cylinder head screws with 8mm screw head
diameter. The screws and rawl plugs are not part of the
standard delivery.
Screw the 2 screws in to the depth indicated.
Hang the appliance from the screws. Pull the appliance
downwards. The upper screw position is level with the two
alignment ribs on the appliance back panel.
Align the appliance horizontally. Tighten the lower screw.
Note
The appliance can be additionally secured at the optional
anchorage points.
Using a screwdriver and working from behind, break
out the upper marked anchorage points in the back
panel.
Position the mounting template over the existing
screws. Mark out the upper holes.
Drill the holes for the two optional anchorage
points. Use appropriate rawl plugs.
Hang the appliance from the screws. Pull the appli-
ance downwards.
Align the appliance horizontally. Tighten the lower
screw.
Insert the 2 additional screws.