INSTALLATION
Maintenance
Activating the safety switch (AE 3)
D0000040076
Registering/ deregistering the wireless remote control at the
DCE11/13RC
D0000048647
1
2
1 Key for registering and deregistering
2 Yellow LED illuminates when wireless remote control is
activated
To start registration of the wireless remote control briefly
press the key. The yellow LED starts to flash. Now press key
"1" on the wireless remote control. A brief flashing of the LED
indicates that registration was successful. The yellow LED
then extinguishes.
To deregister the wireless remote control press the key for
5seconds. A brief flashing of the LED indicates that deregis-
tration was successful. The yellow LED then extinguishes.
Plug-in position of the wireless remote control for
DCE11/13RC
D0000046810
14. Maintenance
WARNING Electrocution
Before any work on the appliance, disconnect all poles
from the power supply.
Draining the appliance
WARNING Scalding
Hot water may escape during the draining process.
For maintenance work or when there is a risk of frost drain the
appliance as follows:
Close the shut-off valve in the cold water inlet pipe.
Open the draw-off valve.
Undo the water connections on the appliance.
Cleaning or replacing filter/flow limiter
D0000040081
1
2
1 Strainer
2 Flow limiter
Remove the filter and flow limiter with the aid of a pointed
object or suitable pliers.
Appliance storage
Store the dismantled appliance in a room free from the risk
of frost, as water residues remaining inside the appliance can
freeze and cause damage.