INSTALLATION
Safety
6 | DCE-S Plus www.stiebel-eltron.com
INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
!
Material losses
Observe the maximum inlet temperature. Higher tem-
peratures may damage the appliance. You can limit the
maximum inlet temperature by installing a central ther-
mostatic valve.
WARNING Electrocution
This appliance contains capacitors which are discharged
when disconnected from the power supply. The capacitor
discharge voltage may briefly exceed60VDC.
6.2 Shower operation
CAUTION Burns
f When supplying a shower, set the internal anti-
scalding protection to 55°C or less; see chapter
"Commissioning/ Preparations".
CAUTION Burns
If operating with preheated water, e.g. if using a solar
thermal system, observe the following information:
The DHW temperature may exceed the set temperature
or a set temperature limit.
f In this case, limit the temperature with an upstream
central thermostatic valve.
6.3 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
- The protection rating IP25 (hoseproof) is only guaranteed
with a properly fitted cable grommet and the use of counter-
sunk screws Ø4.5mm with a max. head diameter of 9mm.
- The electrical resistivity of the water must not fall below that
stated on the type plate. In a linked water network, take into
consideration the lowest electrical resistivity of the water.
Your water supply utility will advise you of the electrical re-
sistivity or conductivity of the water in your area.
7. Appliance description
7.1 Standard delivery
The following are delivered with the appliance:
- 2 x 45° twin connectors
- 2 flat gaskets
- 2 O-rings
- Cable grommet
- Strainer
- Flow limiter
- Jumper for anti-scalding protection, attached
- Jumper for output changeover, attached
7.2 Accessories
Installation kit for water installation on unfinished walls
(200016 - UP-Kit EU)
The installation kit for water installation on unfinished walls con-
tains:
- 2 x grommets to seal the apertures in the appliance back
panel.
- Strainer with sealed edge for installation on the 45°twin
connector.
- Flat gasket
8. Preparation
8.1 Installation site
!
Material losses
Install the appliance in a room that is free from the risk
of frost.
f Always install the appliance vertically and near the draw-off
point.
The appliance is suitable for undersink and oversink installation.
Undersink installation
D0000073616
1
2
1 Cold water inlet
2 DHW outlet