84�02�02�0025�
x Flow rate in l/min
Y Temperature increase in K
1 3.0kW
2 4.4kW
3 6.6kW
4 8.8kW
Beispiel DHC 4 mit 4.4 kW
Durchflussmenge 2.5 l/min
Temperaturerhöhung 25 K
Kaltwasserzulauftemperatur 10 °C
Auslauftemperatur 35 °C
15.4 Application areas
See chapter "Data table".
15.5 Details on energy consumption
Product data complies with EU regulations relating to the Directive
on the ecodesign of energy related products (ErP).
DHC 3 DHC 4 DHC 6 DHC 8 DHC 6 U
073478 073715 073480 073481 073479
Manufacturer STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON STIEBEL ELTRON
Load profile XXS XXS XXS XS XXS
Energy efficiency class A A A A A
Annual power consumption kWh 505 505 522 477 522
Energy conversion efficiency % 37 37 36 39 36
Sound power level dB(A) 15 15 15 15 15
Special information on measuring efficiency None None None None None