INSTALLATION
Safety
22 | SNE 5 t ECO www.stiebel-eltron.com
INSTALLATION
7. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
7.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
7.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
8. Appliance description
The open vented (non-pressurised) appliance is only suitable
for undersink installation. The appliance is intended to heat cold
water for supplying a single draw-off point.
The appliance must only be installed with an open (non-pres-
surised) tap (see chapter "Installation/ Appliance description/
Accessories").
8.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
8.2 Accessories
8.2.1 Required accessories
The following taps are available as accessories for open vented
operation:
Mixer taps
- WST, WUT
Mono-lever mixer taps
- MEW, MES, MEWC
Sensor taps
- WSN
8.2.2 Additional accessories
- Strainer for the "cold water inlet" connection
9. Preparation
Flush the water line thoroughly.
Water installation
No safety valve is required.
Taps/valves
!
Material losses
Sealed unvented taps are not permitted.
Install a tap for open vented operation.
9.1 Installation site
!
Material losses
Install the appliance in a room that is free from the risk
of frost.
!
Material losses
Mount the appliance on the wall. The wall must have
sufficient load bearing capacity.
!
Material losses
The appliance is only suitable for undersink installation.
The water connections of the appliance are at the top.
Note
Make sure that the appliance is
freely accessible for maintenance work.
Always install the appliance vertically and near the draw-off point.
820
520-570
D0000071787
850
550-600
D0000071788