8
Info temperatures
The menu item INFO TEMP enables you to
scan the heat pump or heat pump system
sensor temperatures, comparing set with
actual values, the heating curve gap, etc. In all,
the following 22 parameters can be scanned:
Outside temperature
Actual room temperature
(HC 1/HC 2)
(will only be displayed if the FE 7 remote
control is connected)
Set room temperature (HC 1/HC 2)
(will only be displayed if the FE 7 remote
control is connected)
Actual DHW temperature
Set DHW temperature
Actual HP return temperature (HC 1)
Set HP return temperature (HC 1)
The fixed temp. will be displayed for
fixed temperature control
Actual mixer ow temperature (HC 2)
Actual mixer ow temperature (HC 2)
Fixed HP return temperature
Set buffer temperature
Highest set value of heating circuits H1,
H2, H3 if MSM is installed. Fixed tempe-
rature will be displayed for fixed tempe-
rature control)
Actual HP ow temperature
Set DHW ow temperature
Set heating ow temperature
Actual source ow temperature
Set source ow temperature
CHG PT HTG
CHG PT DHW
Heating limit temperature
Limit temperature DHW
System frost protection temperature
Frost protection temperature IWS 1 to
IWS 6
Open the control ap!
Heating curves
The HTG CURVE menu item enables you
to adjust one heating curve each for heating
circuit 1 and 2. Selecting the correct heating
curve is therefore vitally important.
Note:
Your contractor will have set up a building
and system-specic optimum heating curve
for every heating circuit. It relates to the HP
return temperature for heating circuit 1 and
to the mixer ow temperature for heating
circuit 2.
When adjusting the heating curve on WPM,
the calculated set return or flow temperature,
which is subject to the outside temperature
and the set room temperature, will be shown
at the top of the display.
Bezogen auf +20 °C
Außentemperatur
Bezogen auf 0 °C
Außentemperatur
Bezogen auf -20 °C
Außentemperatur
Tag-Betrieb Heizkreis 1
Bezogen auf +20 °C
Außentemperatur
Bezogen auf 0 °C
Außentemperatur
Bezogen auf -20 °C
Außentemperatur
Absenk-Betrieb
Based on 20°C
Outdoor temp
Based on 0°C
Outdoor temp
Based on -20
Outdoor temp
Set-Back operation
Day operation Heating Circuit 1
Based on +20°C
Outdoor temp
Based on 0°C
Outdoor temp
Based on -20
Outdoor temp
26_03_01_0076
As soon as a temperature has been pre-se-
lected via the fixed temperature parameter at
control level 3, heating circuit 1 will be hidden,
and the display will show FIXED TEMP with
the relevant temperature.
Year STOP
Month STOP
Day STOP
Holiday
Back
Holiday / Party
Note:
Actual or set temperatures will not be dis-
played, if the corresponding sensor is not
connected.
Temperatures
Outdoor
Back
Temperatures