EasyManua.ls Logo

Stihl FSE 41 - Connecting to Power Supply; Strain Relief

Stihl FSE 41
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FSE 31, FSE 41
English
13
FSE 41 only
N Rotate the control handle (1) 180°
relative to shaft and engage it in
position – see “Adjusting the
Handles”.
N Swing the motor housing (2) 45°
and engage it in position, see
“Adjusting Shaft Angle”
The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Extension cord
The design of the extension cord must at
least fulfill the same features as the
connecting cord on the machine.
Observe the design marking (type
designation) on the connecting cord.
The cores in the cord must have the
following minimum cross-section
depending on the mains voltage and
cord length.
N Insert the plug (1) into the extension
cord coupling (2).
Strain Relief
The strain relief (cord retainer) protects
the connecting cord against damage.
N Make a loop in the extension cord.
N Pass the loop (3) through the
opening (4).
N Slip the loop (3) over the hook (5)
and pull it tight.
N Connect the extension cord plug to
a properly installed wall outlet.
Converting Unit to Power
Edger
1
280BA012 KN
2
Connecting to Power Supply
Cord length Minimum cross-
section
220 V – 240 V:
Up to 20 m 1.5 mm
2
20 m to 50 m 2.5 mm
2
100 V – 127 V:
Up to 10 m AWG 14 / 2.0 mm
2
10 m to 30 m AWG 12 / 3.5 mm
2
2
280BA013 KN
1
3
4
280BA014 KN
5

Related product manuals