FSE 31, FSE 41
English
13
FSE 41 only
N Rotate the control handle (1) 180° 
relative to shaft and engage it in 
position – see “Adjusting the 
Handles”.
N Swing the motor housing (2) 45° 
and engage it in position, see 
“Adjusting Shaft Angle”
The voltage and frequency of the 
machine (see rating plate) must match 
the voltage and frequency of the power 
connection.
The minimum fuse protection of the 
power connection must comply with the 
specifications – see "Specifications".
The machine must be connected to the 
power supply via an earth-leakage 
circuit breaker to disconnect the power 
supply if the differential current to earth 
exceeds 30 mA.
The power connection must correspond 
to IEC 60364 and relevant national 
regulations.
Extension cord
The design of the extension cord must at 
least fulfill the same features as the 
connecting cord on the machine. 
Observe the design marking (type 
designation) on the connecting cord.
The cores in the cord must have the 
following minimum cross-section 
depending on the mains voltage and 
cord length.
N Insert the plug (1) into the extension 
cord coupling (2).
Strain Relief
The strain relief (cord retainer) protects 
the connecting cord against damage.
N Make a loop in the extension cord.
N Pass the loop (3) through the 
opening (4).
N Slip the loop (3) over the hook (5) 
and pull it tight.
N Connect the extension cord plug to 
a properly installed wall outlet.
Converting Unit to Power 
Edger