0458-786-0121-A
41
English
18 Troubleshooting
WARNING
Unconfined sparks may occur if the starter grip is pulled after
the spark plug boot has been removed. Sparks may cause a
fire or an explosion in an easily combustible or explosive
environment. This can result in serious or fatal injuries and
damage to property.
Move the Master Control lever to position and hold it
there before pulling the starter grip.
Move the Master Control lever to position and hold it
there.
Pull the starter grip (3) and guide it back several times.
The combustion chamber is cleared.
Insert and tighten down the spark plug.
Connect the spark plug boot (3) and press it down firmly.
Place the shroud (2) in position.
Rotate the shroud fasteners (1) clockwise until you hear a
click.
The shroud fasteners are locked.
0000-GXX-5806-A0
3

Table of Contents