EasyManua.ls Logo

Store It Cold CoolBot PRO - Page 44

Store It Cold CoolBot PRO
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
WWW.STOREITCOLD.COM
SUPPORT@STOREITCOLD.COM
44
2019 © Store It Cold, LLC. Rev 2019-04A All Rights Reserved.
B. FOR COOLERS WITH OPTIONAL HANGING JOISTS (with or without roof)
Measure and cut a 2" sheet of R-max to fit between the outer wall top plate and double
ceiling joist.
Install the insulation and use spray foam to fill any gaps form both the inside and outside of
the cooler.
Spray insulation in the gap between the double joists also.
PRO TIP
If the insulation is loose and falls out drive a few nails or screws on an angle to temporarily hold the
insulation in place. Once the spray foam cures the nails can be removed and the insulation will remain
in place.