RECEPTACLE
STATION
3-229015-010
1 2
0 0
RC OT
0 0
9 9 9
I I I
I I I
I I I
I I I
o
r ___ .o_CJ.._.o.. ___ 7
I 1 2 OT I
I CONTROL I
I CONSOLE I
L ___________ _J
NOTE 2
~-+------l CD8 0
PACK
1
DIM
1-24
'-----+---; C D8 0
PACK
5
DIM
97-120
SYSTEM HOOKUP
INTERNAL WIRING
( 2) 20
2
5 -------
2
6 -------
PAIR
PAIR
CONTROL
·TERMINALS
Receptacle Station note:
Splice to leads 601, 602, A 1, A2,
A3, A4 in receptacle station for
first 4 1.2Kw Packs (dimmers
1-96). Use leads 81, 82, 83, 84
for 1 .2Kw packs 5 to 12
(dimmers 97-288) . Leads
marked RF1-RF4 are not used.
"TWISTED PAIR
"TWISTED PAIR
LOAD
TERM! NALS
-----;;=:;:----112
NOTE 2
All AC wires must be run in separate conduit,
and may not be combined with control wires or
cables. See inside top cover of pack for input
power wiring instructions.
NEUTRAL
BUSS
Note:
II
II
1.
2.
3.
4.
5.
6.
(II)
3</J 4 wire 120/208VAC or 1</> 3 wire 120/240VAC main feed (bottom entry only).
To loads as required (left side conduit entry only). 2 wire circuits .
Air entry
Warm air exhaust• keep clear.
Two (2) twisted pair
BELDEN #9744 or #9156 (A 1, A2, A3, A4) and two (2) #20 AWG (601,602)
in conduit (for
COBO 1.2Kw Packs 111-4).
Two (2) twisted pair BELDEN #9744 or #9156 (81, 82, 83, 84) and two (2) #20 AWG (601,602)
in conduit for COBO
1.2Kw Packs #5-12).
Use BELDEN #9744 cable up to 1000 feet, and BELDEN /19156 cable up to 2000 feet.
Figure 7. CD80 1.2Kw Pack (Hardwired Control) Installation
27