CAUTION! GFCI BREAKER USE REQUIREMENT
If N.E.C. (National Electric Code) or your local code
requires GFCI (Ground Fault Circuit Interrupter) protection,
you MUST use a GFCI breaker in lieu of a GFCI receptacle.
CAUTION! ADVERSE CONDITIONS / SPACING ISSUES
Performance issues caused by adverse conditions are NOT warranted.
To prevent damage to end panels due to condensation, apply industrial grade
silicone sealant and tightly join to opposite end panels. When not adjoining
cases, keep end panels at least 6away from walls and structures. Rear
panels must also be kept at least 6” from walls and structures.
Case must not be exposed to direct sunlight or any heat source.
To maintain proper case temperature, keep case at least 15-feet from exterior
doors, overhead HVAC vents or any air curtain disruption.
Self-contained case clearance: 6” min. air intake / 6” min. air discharge.
CAUTION
CAUTION! LAMP REPLACEMENT GUIDELINES
All lamps reflect specific size, shape, breakage resistance and overall
design. Replacements must meet factory specifications.
CAUTION
PRECAUTIONS
This sheet contains important precautions to prevent
damage to unit or merchandise.
Please read carefully!
See previous page for specifics on OVERVIEW,
TYPE, COMPLIANCE and WARNINGS.
WIRING DIAGRAM
Each case has its own wiring diagram folded and in its
own packet.
Wiring diagram placement may vary; it may be placed
near ballast box, field wiring box, raceway cover, or
other related location.
REFRIGERANT DISCLOSURE STATEMENT
This equipment is prohibited from use in California with
any refrigerants on the List of Prohibited Substances
for that specific end-use, in accordance with California
Code of Regulations, title 17, section 95374.
This disclosure statement has been reviewed and
approved by Structural Concepts and Structural
Concepts attests, under penalty of perjury, that these
statements are true and accurate.
CAUTION! POWER CORD AND PLUG MAINTENANCE
Risk of electric shock. If cord or plug becomes damaged,
replace only with cord and plug of same type.
OVERVIEW / TYPE / COMPLIANCE / WARNINGS / PRECAUTIONS / WIRING / PLUGS - PAGE 2 of 2
CAUTION! CHECK CONDENSATE PAN, ITS POSITION & PLUG!
Water on flooring can cause extensive damage!
Before powering up case, check that condensate pan is positioned
directly under cases condensate drain.
Before powering up case, check that condensate pans electrical plug is
SECURELY connected to condensate systems receptacle.
If wicking material is used in condensate pan, check that it is secure.