D19 MicVALVE
E1/8 Come in! Date printed: 9.2.2000
1.4.4 Primary Fuse
Danger: The primary fuse is located inside the D19 MicVALVE. Repair work may
only be performed by a trained service technician. The primary fuse must be
replaced by a spare fuse of exactly the same type and value. The unit must
not be opened by the user – the risk of a severe electric shock hazard is in-
creased as a result of the high operating voltage of the vacuum tubes
(300 V)!
Spare fuse: T 2.0 A H 250 V UL, CSA (5 × 20 mm) Order No. 51.01.1022
1.4.5 Operating Conditions
Ambient air temperature: +10°...+40°C
Relative humidity: Category F (DIN 40040)
1.4.6 Safety and EMC Standards
Safety: Protection class I according to EN 60950; 1992 + A1/A2; 1993 (UL
1950)
EMC: Product family standard for audio, video, audio-visual, and entertainment
lighting control apparatus for professional use.
Emission: EN 50081-1; 1992
Immunity: EN 50082-1; 1992
1.4.7 Mechanical Data
Weight: approx. 5 kg, all options installed.
Dimensions: [mm]
482.4
365
88.3
approx. 19
(BNC)
approx. 19
(knobs)
approx. 8
(rubber feet)