Quick guide V 6.1.0 21
Level
Nr
VarioTrack parameter description
Factory value
Expert
10150
Contact active on event (AUX 2)
Expert
10199
VarioTrack is ON (AUX 2)
No
Expert
10145
VarioTrack is OFF (AUX 2)
No
Expert
10309
Remote entry (AUX 2)
No
Expert
10151
Battery undervoltage (AUX 2)
No
Expert
10334
Battery undervoltage
10/20/40 Vdc
Expert
10152
Battery overvoltage (AUX 2)
No
Expert
10153
Earth fault (AUX 2)
No
Expert
10154
PV error (48h without charge) (AUX 2)
No
Expert
10156
Overtemperature (AUX 2)
No
Expert
10158
Bulk charge phase (AUX 2)
No
Expert
10159
Absorption phase (AUX 2)
No
Expert
10160
Equalization phase (AUX 2)
No
Expert
10161
Floating (AUX 2)
No
Expert
10162
Reduced floating (AUX 2)
No
Expert
10163
Periodic absorption (AUX 2)
No
Expert
10164
Contact active according to battery voltage (AUX 2)
Expert
10165
Battery voltage 1 activate (AUX 2)
No
Expert
10166
Battery voltage 1 (AUX 2)
11.7/23.4/46.8 Vdc
Expert
10167
Delay 1 (AUX 2)
1 min
Expert
10168
Battery voltage 2 activate (AUX 2)
No
Expert
10169
Battery voltage 2 (AUX 2)
11.9/23.9/47.8 Vdc
Expert
10170
Delay 2 (AUX 2)
10 min
Expert
10171
Battery voltage 3 activate (AUX 2)
No
Expert
10172
Battery voltage 3 (AUX 2)
12.1/24.2/48.5 Vdc
Expert
10173
Delay 3 (AUX 2)
60 min
Expert
10174
Battery voltage to deactivate (AUX 2)
13.5/27/54 Vdc
Expert
10175
Delay to deactivate (AUX 2)
60 min
Expert
10176
Deactivate if battery in floating phase (AUX 2)
No
Expert
10177
Contact active according to battery temperature (AUX 2)
With BSP or BTS
Expert
10178
Contact activated with the temperature of battery (AUX 2)
No
Expert
10179
Contact activated over (AUX 2)
3 °C
Expert
10180
Contact deactivated below (AUX 2)
5 °C
Expert
10181
Only activated if the battery is not in bulk phase (AUX 2)
No
Expert
10182
Contact active according to SOC (AUX 2) Only with BSP
Expert
10183
Contact activated with the SOC 1 of battery (AUX 2)
No
Expert
10184
Contact activated below SOC 1 (AUX 2)
50 % SOC
Expert
10185
Delay 1 (AUX 2)
12 hours
Expert
10186
Contact activated with the SOC 2 of battery (AUX 2)
No
Expert
10187
Contact activated below SOC 2 (AUX 2)
30%
Expert
10188
Delay 2 (AUX 2)
0.2 hours
Expert
10189
Contact activated with the SOC 3 of battery (AUX 2)
No
Expert
10190
Contact activated below SOC 3 (AUX 2)
20%
Expert
10191
Delay 3 (AUX 2)
0 hours
Expert
10192
Contact deactivated over SOC (AUX 2)
90 % SOC
Expert
10193
Delay to deactivate (AUX 2)
0.2 hours
Expert
10194
Deactivate if battery in floating phase (AUX 2)
No
Expert
10195
Reset all settings (AUX 2)
-