EasyManuals Logo

Studer RCC-02 Quick Guide

Studer RCC-02
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Studer Innotec SA
Quick guide RCC-02/-03
20 V 6.1.0 Quick guide
Level
Nr
VarioTrack parameter description
Factory value
Expert
10105
Absorption phase (AUX 1)
No
Expert
10106
Equalization phase (AUX 1)
No
Expert
10107
Floating (AUX 1)
No
Expert
10108
Reduced floating (AUX 1)
No
Expert
10109
Periodic absorption (AUX 1)
No
Expert
10110
Contact active according to battery voltage (AUX 1)
Expert
10111
Battery voltage 1 activate (AUX 1)
No
Expert
10112
Battery voltage 1 (AUX 1)
11.7/23.4/46.8 Vdc
Expert
10113
Delay 1 (AUX 1)
1 min
Expert
10114
Battery voltage 2 activate (AUX 1)
No
Expert
10115
Battery voltage 2 (AUX 1)
11.9/23.9/47.8 Vdc
Expert
10116
Delay 2 (AUX 1)
10 min
Expert
10117
Battery voltage 3 activate (AUX 1)
No
Expert
10118
Battery voltage 3 (AUX 1)
12.1/24.2/48.5 Vdc
Expert
10119
Delay 3 (AUX 1)
60 min
Expert
10120
Battery voltage to deactivate (AUX 1)
13.5/27/54 Vdc
Expert
10121
Delay to deactivate (AUX 1)
60 min
Expert
10122
Deactivate if battery in floating phase (AUX 1)
No
Expert
10123
Contact active according to battery temperature (AUX 1)
With BSP or BTS
Expert
10124
Contact activated with the temperature of battery (AUX 1)
No
Expert
10125
Contact activated over (AUX 1)
3 °C
Expert
10126
Contact deactivated below (AUX 1)
5 °C
Expert
10127
Only activated if the battery is not in bulk phase (AUX 1)
No
Expert
10128
Contact active according to SOC (AUX 1) Only with BSP
Expert
10129
Contact activated with the SOC 1 of battery (AUX 1)
No
Expert
10130
Contact activated below SOC 1 (AUX 1)
50 % SOC
Expert
10131
Delay 1 (AUX 1)
12 hours
Expert
10132
Contact activated with the SOC 2 of battery (AUX 1)
No
Expert
10133
Contact activated below SOC 2 (AUX 1)
30%
Expert
10134
Delay 2 (AUX 1)
0.2 hours
Expert
10135
Contact activated with the SOC 3 of battery (AUX 1)
No
Expert
10136
Contact activated below SOC 3 (AUX 1)
20%
Expert
10137
Delay 3 (AUX 1)
0 hours
Expert
10138
Contact deactivated over SOC (AUX 1)
90 % SOC
Expert
10139
Delay to deactivate (AUX 1)
0.2 hours
Expert
10140
Deactivate if battery in floating phase (AUX 1)
No
Expert
10141
Reset all settings (AUX 1)
-
Expert
10142
AUXILIARY CONTACT 2
Expert
10143
Operating mode (AUX 2)
Automatic
Expert
10144
Combination of the events for the auxiliary contact (AUX 2)
Any (Function OR)
Expert
10146
Contact activated in night mode (AUX 2)
Expert
10147
Activated in night mode (AUX 2)
No
Expert
10148
Delay of activation after entering night mode (AUX 2)
1 min
Expert
10149
Activation time for the auxiliary relay in night mode (AUX 2)
1 min
Expert
10322
Contact active with a fixed time schedule (AUX 2)
Expert
10323
Contact activated with fixed time schedule (AUX 2)
No
Expert
10324
Start hour (AUX 2)
07:00 hh:mm
Expert
10325
End hour (AUX 2)
20:00 hh:mm

Other manuals for Studer RCC-02

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer RCC-02 and is the answer not in the manual?

Studer RCC-02 Specifications

General IconGeneral
BrandStuder
ModelRCC-02
CategoryRemote Control
LanguageEnglish