Start-up STULZ UltraWater 3-stage reverse osmosis system SUW
© STULZ GmbH, Hamburg
-
32
-
8. START-UP
The drain water connection must be ensured.
Do not use mains water with a temperature above 45°C.
Protect the system against frost.
If the system is disconnected from the mains water for more than 5 days, the
system must be disconnected from the mains electricity and the water drained
from the system.
Avoid water hammer! The pre-pressure may not exceed 10 bar in any time!
Note:
If the SUW is operated without the housing, the warning sign „W08“ must
be installed at a visible location!
If contamination of chalk must be avoided because of sensitive applications. Wait for the
required conductance before lling the water tank.