EasyManua.ls Logo

Sullair 3007 - Lubrication Change Recommendations and Maintenance, Fluid Filter and Separator

Sullair 3007
146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.6
LUBRICATION CHANGE RECOMMENDATIONS AND MAINTENANCE, FLUID
FILTER AND SEPARATOR
LUBRICANT FLUID CHANGE FLUID FILTER CHANGE SEPARATOR CHANGE
Sullube A, E G, C A, D
SRF 1/4000 B, E G, C B, D
24KT F, E G, C A, D
CP-4600-32-F B, E G, C B, D
A - 8,000 hours or once a year.
B - 4,000 hours or more frequently if conditions so require.
C - When measured pressure loss exceeds 20 psig (1.3 bar).
D - When measured pressure loss exceeds 10 psig (0.7 bar).
E - When required by fluid analysis or known contamination.
F - Does not require replacement during normal service conditions.
G - Every 2,000 hours.
SPECIFICATIONS
®SULLAIR®
3000-4500 Operator’s Manual and Parts List
21

Table of Contents