EasyManua.ls Logo

Sullair 425 - Part Replacement and Adjustment Procedures; Compressor Fluid Change Procedure; Compressor Fluid Filter Element Replacement; Air Filter Maintenance

Sullair 425
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
65
375 John Deere Standard and Aftercooled/Filtered Operator’s Manual and Parts List
MAINTENANCE
PART REPLACEMENT AND 5.8
ADJUSTMENT PROCEDURES
Compressor Fluid Change Procedure
Run the compressor ve to ten minutes to warm the 1.
uid.
Shut the compressor down and relieve all internal 2.
pressure.
Drain the uid sump by removing the plug, or opening 3.
the valve at the bottom of the sump tank.
Change the compressor uid and replace the uid 4.
lter element (For element replacement see the lter
servicing procedure in this Section.)
Fill the sump with uid in accordance with the 5.
specications in Section 3.
Compressor Fluid Filter Element
Replacement
Refer to Figure 5-1.
Remove the old element with a strap wrench.1.
Clean the gasket seating surface.2.
Apply a light coating of uid to the new gasket.3.
Hand tighten the new element (P/N 250025-525) until 4.
the new gasket is seated.
Continue tightening the element by hand an additional 5.
1⁄2 to 3⁄4 turn.
Restart the compressor and check for leaks. 6.
Filter Head1.
Fluid Filter2.
Figure 5-1
Air Filter Maintenance
Refer to Figure 5-2. Air lter maintenance should be
performed as often as conditions require. If the lters are
equipped with optional maintenance indicators, change the
lters every time the indicators show a change is
necessary.
Filter Body1.
Filter Cover2.
Safety (Secondary) Element**3.
Primary Element* 4.
*Replacement Primary Element
P/N 02250164-532
**Replacement Safety (Secondary) Element
P/N 02250164-533
Figure 5-2
Air Filter Replacement
Loosen and remove the air lter and cover.1.
Remove the primary and secondary elements.2.
Clean the body, inside and out, with a damp cloth.3.
Reinstall (if clean) or replace the secondary element.4.
Replace the new primary lter element.5.
Reposition the cover and lock it into the position.6.
Reset the lter restriction indicator (if equipped). 7.
2
1
SU_0000669
SU_0000678

Table of Contents

Other manuals for Sullair 425