Section 2
DESCRIPTION
9
Figure 2-3A Compressor Piping and Instrumentation Diagram- LS16T 100/125 Air-cooled
key part
number description number quantity
1 filter, air 02250059-096 1
2 valve, poppet 02250083-783 1
3 compressor, 1st stage unit 1
4 xdcr, press 0-500# 1-5vdc n4 02250085-652 4
5 p, rtd 100 ohm 250039-909 4
6 compressor, 2nd stage unit 1
7 valve, discharge check 016732B 1
8 sw,vac 22”wc n4 6’ cable 02250078-249 1
9 tank, sump 02250134-216 1
10 valve, ball 3/4” 02250117-792 2
11 glass, sight 02250097-611 1
12 valve, relief-400 psi 02250137-688 1
13 valve, pressure regulator 045099 1
14 aftercooler, air 02250138-182 1
15 valve,check 1/2” 042694 1
16 valve, minimum pressure 250022-735 1
17 regulator, down stream 046556 2
18 element, separator primary 250034-115 1
19 fltr, coalescing 425# 02250058-442 1
20 cooler, oil 02250138-183 1
21 strainer, oil return 02250117-782 2
22 element, thermal vlv 220 degf 250001-349 1
23 element, separator secondary 250042-861 1
24 filter, oil injection 02250121-658 1
25 separator, water 250001-873 1
26 trap, drain 250006-639 1
27 orifice, .040” 1/4”m x 1/4”f 02250091-395 2
28 gauge, pressure 02250117-009 2
29 valve, oil stop 02250113-668 1
30 orifice, 0.032” 02250125-774 1
31 valve, check 1/4” - viton seat 02250110-557 3
32 restrictor, pipe .375” dia 866406-000 1
33 valve, running blowdown n.c. 045116 1
34 orifice, .063” 02250125-775 1
35 valve, solenoid 3-way n.o. 407390 2