SECTION 3 TS32 USER MANUAL
29
3.5 LUBRICATION GUIDE—24KT
COMPRESSORS
Refer to Figure 3-1. Sullair 24KT compressors are
filled with a lubricant which rarely needs to be
changed. In the event a change of fluid is required,
use only Sullair 24KT fluid.
Sullair recommends that a 24KT sample be taken at
the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with
instructions and self-addressed container is to be
supplied by your Sullair Representative at start-up.
The user will receive an analysis report with
recommendations.
3.6 LUBRICATION GUIDE—
OPTIONAL FLUID
Refer to Figure 3-1. Sullair compressors may use
SRF 1/4000 fluid as an optional factory fill.
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under
severe operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong
oxidizing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still
recommended as indicated in the Operator's Manual.
WARNING
Before changing or recharging system fluid
always relieve all pressure from the sump
tank and all compressor lines.
NOTE
DO NOT mix different types of fluids.
MIXING OF OTHER LUBRICANTS WITHIN
THE COMPRESSOR UNIT WILL VOID ALL
WARRANTIES.
Flush system when switching lubricant
brands.
Figure 3-1: Fluid Fill Location
WARNING
Before changing or recharging system fluid
always relieve all pressure from the sump
tank and all compressor lines.
NOTE
DO NOT mix different types of fluids.
MIXING OF OTHER LUBRICANTS WITHIN
THE COMPRESSOR UNIT WILL VOID ALL
WARRANTIES.
Flush system when switching lubricant
brands.