Sun Fire X4150 Server Product Notes 15
“Front USB Port Cable Limitations” on page 25
“Prevent Inadvertent Disconnection of the DVD Assembly When Removing USB
Front Panel Devices” on page 25
Hard Drives Can Be Difficult to Remove From
Right-Side Drive Bays
Hard Drives in the right-side drive bays can be difficult to remove.
Workaround
Until a mechanical fix is implemented, use the following procedure to remove hard
drives from right-side drive bays.
1. Press the drive to the right. See Step 1 in the following figure.
2. Push in on the drive, while holding it pressed to the right. See Step 2 in the
following figure.
3. Press the drive eject button and pull on the eject lever. See Step 3 in the
following figure.
4. Use the eject lever to slide the drive out of the bay.