Sun Fire X4150 Server Product Notes 35
2. Click the Configuration main tab.
3. Click the Clock Setting submenu tab.
4. Select the NTP server radio button for clock synchronization.
5. Enter the NTP server IP address in the IP address field.
6. Click Submit.
IPMItool 1.8.8 Returns Incorrect Memory Information
Direct Reading of the SPD memory is not supported in IPMItool 1.8.8. Using the
IPMItool fru print command will result in a return of incorrect memory
information. An updated IPMItool utility is required for this to work properly.
Software support has been added for the server.
IPMItool Commands Might Not Be Able to Establish a
Network Connection to the SP
If the SP firmware becomes corrupt, IPMItool commands might not complete or fail
to establish a LAN session connection.
Workaround: Using the SP update utility on the Tools and Drivers CD, reflash the SP
firmware using the following command.
upfw s92xxx.bin
Where xxx is the current version of the SP firmware.
Note – This will set the SP back to factory defaults and will remove all current
settings, including users and permissions and rules. Use this procedure with
caution.
Disabling the Web Interface Time-out Function
It is best to disable the web GUI time-out function when performing remote
installations.
▼ Disabling the Web Interface Time-out Function
1. Login to the ELOM web GUI.