EasyManua.ls Logo

Sun Microsystems Sun Fire X4150 - Fixed Issues

Sun Microsystems Sun Fire X4150
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sun Fire X4150 Server Product Notes 61
Incorrect Jumper Description in Service Manual
The Sun Fire X4150 Server Service Manual, 820-1852-10, contains errors in the
procedure to reset BIOS password using a jumper.
Pages 4-33 through 4-35 refer to using jumper J33 to reset the CMOS NVRAM and
change the BIOS password. This is incorrect.
The correct jumper is J23 to both reset the CMOS NVRAM and BIOS password. This
jumper is located near the CR 2032 battery, below the PCIe riser 0.
The remainder of the procedure is correct, and can be followed using the J23 jumper.
Fixed Issues
The following issues have been resolved:
Issues Fixed in Sun Fire X4150 and X4250
Software Supplemental
Refer to the following sections for information on issues that have been fixed in the
software supplemental releases:
“Issues Fixed In Software Supplemental 3.2.0” on page 61
“Issues Fixed in Software Supplemental 3.0.2” on page 62
“Issues Fixed in Software Supplemental 3.0.1” on page 62
“Issues Fixed in Software Supplemental 2.2.2” on page 63
Issues Fixed In Software Supplemental 3.2.0
The following issue has been fixed in Sun Fire X4150 and X4250 Software
Supplemental 3.2.0:
VMWare issues fixed:
CR 6871221: A server running VMware ESX 4.0 hangs due to a BIOS error.
ILOM Issues fixed:
CR 6887273: ILOM 3.0 Daylight Savings time is inconsistent

Table of Contents

Other manuals for Sun Microsystems Sun Fire X4150

Related product manuals