SSD Configuration With No SAS Drives Installed
Use the following guidelines for installing SSDs when you don’t plan to install
additional SAS drives:
■ The server must be running a minimum BIOS version 1ADQW057.
■ A maximum of 4 SSDs are currently supported.
■ Use cable kit (X)6389A to connect the SSD drives to the motherboard.
This kit needs to be ordered separately when the SSDs are ordered.
■ Use the following guidelines to install the SSDs:
For HDD slots 0-3:
■ Drives 0-3 plug into the Enterprise South Bridge (ESB) connection on the
motherboard.
■ SSDs or fillers must be used for drive slots 0-3.
■ No SAS HDD can be plugged into slots 0-3, as the ESB does not work with
SAS.
For HDD slots 4-7:
■ No drives can be installed in these slots.
■ Filler panels must be installed in these slots.
SSD Configuration With SAS Drives Installed
Use the following guidelines for installing SSDs when you do plan to install
additional SAS drives:
■ The server must be running a minimum BIOS version 1ADQW057.
■ A maximum of 4 SSDs can be installed.
■ Use cable kit (X)6388A and a SAS HBA to install the drives.
These items need to be ordered separately when the SSDs are ordered.
■ Use an HBA to connect the SATA drives.
■ Use the following guidelines to install the SSDs and additional drives:
For HDD slots 0-3:
■ Drives 0-3 plug into the Enterprise South Bridge (ESB) connection on the
motherboard, using the longer cable with the right angle disk backplane
connector from cable kit (X)6388A.
■ SSDs or fillers must be used for drive slots 0-3.
■ No SAS HDD can be plugged into slots 0-3, as the ESB does not work with
SAS.
For HDD slots 4-7: