EasyManua.ls Logo

Sun Microsystems Sun Fire X4150 - Page 73

Sun Microsystems Sun Fire X4150
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sun Fire X4150 Server Product Notes 71
SNMP Event Traps Not Being Sent for Fan (CR6736433)
When a fan is removed for the system, the Set Platform Event Filter does not set a
trap for the fan.
Add Sensor for PSU Fan Stop Rotation Detection (CR6709927)
When PSU fan rotation stops, it is recorded as an error in SEL and the PSU fail LED
is lit.
Issues Fixed in Tools and Drivers CD Version 1.3.2
The following issues are fixed with Tools and Drivers CD version 1.3.2.
New PSU Flow Chart Implemented (CR6699241)
With this firmware release, the system is able to detect if the PSU or power cord is
removed and records an error in SEL along with the PSU fail LED.
BIOS Setting Missing (CR6786761)
The BIOS setting terminal type=vt100/ansi was inadvertently omitted after
BIOS version 020 (from 1.2 Tools and Driver CD).
A fix for this issue is planned for a later release of the BIOS.
Issues Fixed in Tools and Drivers CD Version 1.3.1
The following issues are fixed with Tools and Drivers CD version 1.3.1.
Incorrect Syntax in Service Processor SEL log Entry With BMC 4.0.08
When Manually Removing a Fan (CR6656761)
When removing a fan from the server, the SEL will log an event indicating that the
fan is present.

Table of Contents

Other manuals for Sun Microsystems Sun Fire X4150

Related product manuals