Function Parameter Table 21
E500 Series Universal Low-Power Inverter
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modifica-
tion limit
Basic running parameter group
F0.07
Acceleration and
deceleration
characteristic
parameter
0: Straight line
acceleration and
deceleration
1: S Curve
acceleration and
deceleration
1 0
F0.08 Carrier frequency 1.5 ~ 10.0kHz 0.1 8.0
F0.09 Modulation mode
0: Asynchronous
1: Synchronous
1 0 ×
F0.10
Parameter write
and protection
1: Only allowing
to rewrite F0.01
parameter and this
parameter
2: Only allowing
to rewrite this
parameter
Other values: All
parameters are
allowed to be
rewritten.
1 0
F0.11 Torque boost 0.0 ~ 20.0 (%) 0.1 6.0
F0.12
Basic running
frequency
5.0Hz ~ Upper
limiting frequency
0.1 50.0
F0.13
Maximum output
voltage
25 ~ 250V/
50 ~ 500V
1
220/
440
F0.14
Jog acceleration
time
0.1~ 600.0 S 0.1 5.0
F0.15
Jog deceleration
time
0.1~ 600.0 S 0.1 5.0
F0.16
FWD jog
frequency
0.0Hz~[F0.04] 0.1 10.0
F0.17
REV jog
frequency
0.0Hz~[F0.04] 0.1 10.0
F0.18
Auxiliary
function setting
LED Units:
running direction
0: Consistent with
the set direction
1: Reverse to the
set direction
LED Tens: Jog
priority selection
0: Highest
1: Lowest
1 0000
F0.19
Lower limiting
frequency
functioning mode
0: Output lower
limiting frequency
when it is lower
than the lower
limiting frequency
1: Output zero
frequency when it
is lower than the
lower limiting
frequency
1 0