22 Function Parameter Table
E500 Series Universal Low-Power Inverter
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modifica-
tion limit
F0.20 Reserve
F0.21
Parameter
protection
p
assword
0~9999 1 0
F0.22 UP/DW speed 0.1~50.0Hz 0.1 5.0
F0.23 PWM period 1.0~10.0ms 0.1 5.0
F0.24 Reserve
Input and output parameter group
F1.00
AI input lower
limiting voltage
0.0 V ~ [F1.01] 0.1 0.0 F1.00
F1.01
AI input upper
limiting voltage
[F1.00] ~ 10.0 V 0.1 10.0 F1.01
F1.02
AI input
filter time
0.01~1.00S 0.01 0.01 F1.02
F1.03
Minimum set
frequency
0.0Hz ~ [F1.04] 0.1 0.0 F1.03
F1.04
Maximum set
frequency
[F1.03] ~ [F0.04] 0.1 50.0 F1.04
F1.05
Analog output
selection
0: output
frequency
1: output current
2: output voltage
1 0 F1.05
F1.06
AO output
lower limit
0.0V ~ [F1.07] 0.1 0.0 F1.06
F1.07
AO output
upper limit
[F1.06] ~ 10.0V 0.1 10.0 F1.07
F1.08
Function
selection of
input terminal 1
0~29 1 11 F1.08
F1.09
Function
selection of
input terminal 2
0~29 1 1 F1.09
F1.10
Function
selection Of
input terminal 3
0~29 1 2 F1.10
F1.11
Function
selection Of
input terminal 4
0~29 1 3 F1.11
F1.12
Input channel
characteristic
selection
0000~1111H 1 0000 F1.12
F1.13
OC output
function selection
0~15 1 0 F1.13
F1.14
Relay output
TA/TC function
selection
0~15 1 8 F1.14