24 Function Parameter Table
E500 Series Universal Low-Power Inverter
Parameter
Type
Function
Code
Name
Setting Range and
Description
Minimum
unit
Default
setting
Modifica-
tion limit
Input and output parameter group
F1.28
Frequency input
channel
combination
0: External voltage
+ panel
potentiometer
1: External
voltage+ panel
potentiometer +
Digital setting
2:Communication +
external voltage
3: Communication
+ external voltage +
panel potentiometer
4:Communication +
digital-panel
potentiometer
5:Communication -
external voltage
6:Communication +
external voltage -
p
anel potentiometer
7:External voltage
+ digital - panel
potentiometer
8:Panel
potentiometer -
Digital setting
9:UP/DW+
External voltage
10: UP/DW + panel
potentiometer +
external voltage
1 0
F1.29
-
F1.31
Reserve
Auxiliary running parameter group
F2.00 Start frequency 0.0 ~ 50.0Hz 0.1 1.0
F2.01
Start frequency
duratio
n
0.0 ~ 20.0 Sec 0.1 0.0 ×
F2.02 Stop mode
0: Deceleration stop
1: Free stop
1 0
F2.03
Stop DC braking
frequency
0.0~[F0.04] 0.1 3.0
F2.04
Stop DC braking
current
0 ~ 100 (%) 1 10 ×
F2.05
Stop DC braking
time
0.0 ~ 20.0 Sec 1 0.0
F2.06
Acceleration
torque level
110 ~ 200 (%) 1 170
F2.07
Motor overload
protecting
coefficient
50 ~ 110 (%) 1 110
F2.08
Dynamic
braking
Initial
voltage
(1)
300 ~ 400V/
600 ~ 800V
1
370
740
F2.09 Reserve
HRW Limited
admin@hrw.hk
www.hrw.hk

Related product manuals