9 Troubleshooting and Maintenance User Manual
76
Abnormal grounding.
Neither the PE terminal
on the AC connection
block nor the second
PE terminal on the
enclosure is reliably
connected.
Check whether there is a reliable inverter
grounding line, if there is access to the
ground, and the fault persists, please
contact SUNGROW.
Bus hardware
over-voltage fault.
The bus voltage
exceeds the protective
value.
1. Wait for inverter recovery after bus
voltage lower.
2. If the fault occurs repeatedly, contact
SUNGROW.
The bus voltage is too
low.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
SUNGROW.
PV hardware
over-current fault.
The PV1 or PV2
current exceeds the
protective value.
If the fault occurs repeatedly, contact
SUNGROW.
The PV input voltage
exceeds the bus
voltage.
Check the functionality of the PV connection
terminals.
Input and output power
mismatching fault.
If the fault occurs repeatedly, contact
SUNGROW.
PV1 current sampling
fault.
Channel sampling anomaly.
Contact SUNGROW.
PV2 current sampling
fault.
Leakage current
sensor fault.
All temperature
sensors fail.
If the fault occurs repeatedly, contact
SUNGROW.
Ambient temperature
sensor open circuit
warning.
Ambient temperature
sensor short circuit
warning.
If the fault occurs repeatedly, contact
SUNGROW.
Radiator temperature
sensor open circuit
warning.
Radiator temperature
sensor short circuit
warning.