Page 74 of 87
If the shutdown option has been activated for the low pressure monitoring function, the solar
system will be shut down as well in the case of a fault condition. When the pressure reaches
or exceeds the adjustable switch-off pressure value, the system is switched on again.
Note: For the low pressure monitoring function, the switch-off value must be at least
0.1bar higher than the switch-on value. The adjustment ranges will automatically
adapt to that.
UNIT (C-F switch)
Under this menu, below unit can be set:
TEMP: temperature
BAR: pressure
ENERG: heat quantity
The units can be switched during operation.
OSDC( SD Card)
The controller is equipped with a MicroSD card slot for MicroSD memory cards.