23
(2) Setting Softstart Speed
You can change the speed for the first 1-5 stitches by 100 spm.
The above values may not be the same for all machine types. (above is for M and H types)
A. Turn on the memory switch and press to display
“A-02” on the screen.
B. Press to display the present set-up value (1st stitch speed:
400 spm).
C. Press to change to “1-09” (changing to 900 spm).
D. Press (2nd stitch speed 900spm is displayed).
E. Press to change to “2-12” (changing to 1,200 spm)
F. Register the set-up using .
READY
+/FORWARD
SELECT
+/FORWARD
READY
+/FORWARD
Ex) Changing the 1st stitch 400→900 rpm and the 2nd stitch 900→1,200 rpm
A-02
2-09
1-04
1-09
A-02
2-12
1st stitch
2nd stitch
3rd stitch
4th stitch
5th stitch
Scope
400 ~ 900
400 ~ 2700
400 ~ 2700
400 ~ 2700
400 ~ 2700
Default
400 spm
900 spm
2,300 spm
2,300 spm
2,300 spm
For the maximum rotation number, general sewing function No. A-01 (maximum sewing
speed) applies first.
Caution