26
6-3) Memory Switch Functions Table
(1) General sewing functions (A Group)
Turn on the power pressing and . Turn on the memory switch pressing .
P1
General: 100~3,200 2,700 spm
Heavy: 100~3,200 2,700 spm
Light: 100~2,700 2,300 spm
A-01 Setting maximum sewing speed Knitwear: 100~2,700 2,300 spm 100spm
Buttons: 100~2,700 2,300 spm
Hole fixing : 100~3,200 2,700 spm
1st stitch: 400~900 400 spm
2nd stitch: 400~2,000 900 spm
A-02 Setting speed for the first 1-5 stitches
3rd stitch: 400~2,000 2,300 spm 100spm
(Softstart function, different by type)
4th stitch: 400~2,000 2,300 spm
5th stitch: 400~2,000 2,300 spm
A-03
Setting pattern data calling 0 : calling impossible
(You can set for each pattern) 1 : calling possible
A-04
Setting display and change possibility of X,Y scale 0 : change impossible
1
rate and maximum speed limit (prevent errors or mistakes) 1 : change possible
Setting counter function
0 : production counter
A-05 Production counter : addition count
0
Lower thread counter : reduction count
1 : lower thread counter
A-06 Setting center point for scale
0 : original point
0
1 : sewing start point
A-07
Setting whether to search original point after sewing 0 : OFF
0
(sewing with ordinary pattern number) 1 : ON
A-08
Setting whether to search original point after sewing 0 : OFF
0
(sewing with function combination) 1 : ON
A-09 Setting drive scope to infinite
0 : Infinite
1
1 : limited
A-10 Setting starting angel for X, Y drive –100 ~ 100° Belt type : –24°, Direct : –24° 1°
A-11 Setting trimming speed 200 ~ 400spm 400 spm 100spm
A-12 Setting reverse rotation after trimming 0 : OFF, 1 : ON 0
A-13 Setting angle for reverse rotation after trimming 0~70° 0° 1°
A-14 Setting whether to use electronic wiper
0 : OFF
1 : ON
A-15 Faster moving of presser foot after trimming 0 : OFF, 1 : ON 1
A-16
Setting search for original point after certain amount of sewing 0 : OFF
0
(after amount set in A-17) 1 : ON
A-17 Number of automatic search for original point 0~1000 1000 4
A-18 Time for electronic wiper ON 4~1024 ms 100 ms 4 ms
A-19 Canceling trimming
0 : trim ON
0
1 : trim OFF
A-20 Time for solenoid 0 full on (clamp solenoid) 4~72 ms 52 ms 4 ms
A-21 Time for solenoid 1 full on (trimming solenoid) 4~1020 ms 100 ms 4 ms
A-22 Time for solenoid 2 full on (sub solenoid 2) 4~1020 ms 100 ms 4 ms
A-23 Time for solenoid 3 full on (sub solenoid 3) 4~1020 ms 100 ms 4 ms
A-24 Solenoid 0 duty (clamp solenoid) 10~25% 10% 1%
A-25 Solenoid 1 duty (trimming solenoid) 10~25% 20% 5%
A-26 Solenoid 2 duty (sub solenoid 2) 10~25% 20% 5%
A-27 Solenoid 3 duty (sub solenoid 3) 10~25% 20% 5%
A-28 Delay time for clamp solenoid moving up
---
A-29 Delay time for clamp solenoid moving down
A-30 Setting OFF time for electronic wiper 4~1020 ms 4 ms
A-31 Setting whether clamp moves up/down after mid trimming 0 : Down, 1 : Up 1
A-32 Setting pneumatic thread holder 0 : OFF, 1 : ON 0
A-33
Setting integrated/separated pedal
--
(For pneumatic only. Others have integrated pedals)
A-34 Setting whether to use pin hole device
0 : OFF
1 : ON
A-35 Setting whether to use head open/close
0 : OFF
1 : ON
A-36 Whether to use upper stop when turn power on
0 : OFF
1 : ON
A-37 Set time for AC off checking 4 ~ 48 [ms] 20 ms
A-38 Set time for voltage overload checking 4 ~ 1024 [ms] 20 ms
No. Functions and Description Scope Default Unit
1201
1~22 : 1
23~99 : 0
1~33 : 1
34~99 : 0
1~56 : 1
57~99 : 0
1202 1254
1201, 1202
Others Hole fix device
40 ms 100 ms
Others
Only in Direct type
Only in Direct type
1
1
Hole fix device
01
01
1254