38
(3) Using Scalable Pattern ROM
① Installing Scalable Pattern ROM
1) Take the cover off the Bartack control box.
2) As shown in the previous page, install the scalable design ROM onto the “U9” location on the digital board. Make
sure to align the direction with the indication on the board (so the direction mark is on the left). Pin should go into
the socket accurately.
② Using Scalable Pattern
(for BS(BR)1201 series)
Ex) Changing the scalable pattern No.33 and No.34 to call possible
A.
Turn on the power, pressing and at the same time.
Press and then to display “A-03” on the screen.
B. Press to display the present set-up value.
ⓐ part : pattern number, ⓑ part : 0 : call impossible, 1 : call possible
C. Press to change ⓐ “1” to “33”.
D. Press to change ⓑ “0” to “1”.
E. Press to change ⓐ “33” to “34”.
F. Press to change ⓑ “0” to “1”.
G. Press to register.
H. Turn off the power and back on again. Select your desired number.
READY
+/FORWARD
SELECT
+/FORWARD
SELECT
READY
+/FORWARDA
RESETREADY
ⓐⓑ
A-03
33-1
34-0
34-1
A-03
01-1
33-0
1) If the pattern number is set up by default as call impossible, change the set-up of the
pattern to call possible.
2) Check the pattern shape and confirm that the needle and the presser plate do not conflict.
Caution