40
(4) Using Hole Fixing Device
■ SUB machine type
Direct connection type: SPS/E-BS(BR)1201M(HP)
■ Parameter changes and default values for using electronic wiper and hole fixing device
Parameter
Group No.
A-18
A-23
A-27
A-30
A-34
Electronic wiper ON time
Electronic wiper full ON time
Electronic wiper duty value
Electronic wiper OFF time
Pin attach use Yes/No
( 0: NO 1: YES)
Pin attach descending time
Pin solenoid full ON time
Pin solenoid duty value
Pin attach ascending time
Pin attach use Yes/No
( 0: NO 1: YES)
100[ms]
100[ms]
20[%]
40[ms]
0
100[ms]
100[ms]
20[%]
100[ms]
1
Hole fixing deviceElectronic wiper
Content ContentDefault default
■ How to Use
First set the possibility/impossibility of the pattern data call
Ex) Changing exclusive scalable pattern No.33-92 to call possible
A.
Turn on the power, pressing and at the same time.
Press A and then to display “A-03” on the screen.
B. Press to display the present set-up value.
ⓐ part : pattern number, ⓑ part : 0 : call impossible, 1 : call possible
C. Press to change ⓐ “1” to “33”
.
D. Press to change ⓑ “0” to “1”
.
E. Repeat C and D steps to get ⓐ “91”
F. Press to change ⓐ “91” to “92”
G. Press to change ⓑ “0” to “1”
.
H. Press to register.
I. Turn off the power and back on again. Select your desired number
READY
+/FORWARD
SELECT
+/FORWARD
SELECT
READY
+/FORWARD
RESETREADY
ⓐⓑ
A-03
33-1
91-0
92-0
92-1
A-03
01-1
33-0
1) Electronic wiper cannot be used with the hole-fixing device.
2) Initializing to the hole-fixing device version will look like the above table. To use the patterns in
the scalable ROM, you must set YES/NO for the pattern data calling possibility as shown below.
3) For SPS/E-BS1201M(HP) or SPS/E-BR1201M(HP), exclusive scalable pattern is provided.
(No.33 ~ No. 92 )
Caution
If pin hole cannot come up or go down, Er11 will occur. Turn OFF the power, fix the problem
and turn on the power again.
Caution