Page | 70 Hybrid Inverter | Installer Manual
APPENDIX B
Inverters sold in Australia will be set to the Default Australian standards
APPENDIX C
The Sunsynk Three-Phase Hybrid Inverter inverter is compatible with the SolarMan app, via a
Wifi or GSM data logger (See SolarMan instruction manual).
APPENDIX D
If an external Residual Current Device (RCD) is used it should be of Type A/AC with a tripping
current of 30mA or higher.
Use of RCDs
Residual Current Devices (RCDs): An RCD dedicated for an Inverter Energy System (IES) may
be used to meet the mechanical cable protection requirements of AS/NZS3000 for the cable
from the switchboard to the IES. If an RCD is installed the engineer must:
1. Disconnect all live conductors (including both active and neutral conductors) and
2. Be of the type specified in the inverter manufacturer’s instructions or as labelled on the in-
verter.
We recommend the use of an RCD on all circuits and sub-circuits connected to the Sunsynk
Inverter. Below is the specifications for a Residual Current Breaker with Overcurrent Protection
(RCBO).
Earth-leakage protection class Type A
Earth-leakage sensitivity 30mA
Curve code C
Network type AC
Poles description 2P
Earth-leakage protection time delay Instantaneous

Other manuals for SunSynk SUN-10K-SG04LP3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SunSynk SUN-10K-SG04LP3 and is the answer not in the manual?

SunSynk SUN-10K-SG04LP3 Specifications

General IconGeneral
BrandSunSynk
ModelSUN-10K-SG04LP3
CategoryInverter
LanguageEnglish

Related product manuals