4.5.3.2 Clean up cooler.
After the machine works a certain period of
time, the cooler surface will be covered with dust
or other foreign material which will influence
radiating effect of cooler. It should be cleaned in
time.
Open left inspection door( left back door)
Loosen the mounting bots located on left side
of condenser, open up condenser of A/C.
Use compressed air (below 0.2 MPa) or water
to rinse condenser.
Remove the strainer (if present) in front of
radiator for cleaning up.
Use compressed air (below 0.2 MPa) or water
to rinse cooler.
Reinstall the front strainer (if provided) and
condenser of A/C.
Note: Do not remove air conditioning
piping, failure to do so will cause coolant
leakage and lead to air conditioning
malfunction.