Installation
14 NT 10000...NT 12000
Solar inverters may not be stacked in order to prevent excessive warming. In
particular, due to the introduction of cold air from the left side, these devices
must not be suspended above one another in a laterally offset manner.
Ensure sufficient heat dissipation when installing the Solar Inverter in a
switch cabinet or closed room.
The ambient temperature must be within the range -25 to +40 °C. At ambi-
ent temperatures above 40°C, the inverter automatically reduces its output.
The Solar Inverter should not be exposed to direct sunlight to protect it from
unnecessary external warming.
Installation
Proceed as follows to install the Solar Inverter:
1. Hold the wall bracket at the point at which you want to attach the Solar In-
verter and mark the mounting holes.
2. Drill the holes with a 10 mm dia. drill bit. A drilling template with precise
dimensions can be found in the appendix.
3. Install the wall bracket with suitable screws and wall plugs depending on
the surface condition.
4. Release the retaining screws for the Solar Inverter at the top on both sides
with an Allen key.