EasyManua.ls Logo

Sunways NT 10000 - Solar Inverter configuration; Integration into solar system

Sunways NT 10000
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product description
2 NT 10000...NT 12000
Functions resulting from the
German Renewable Energy Act
and the Medium- and Low-Vol-
tage Directive
The Solar Inverter hardware already meets the requirements of the new Medi-
um- and Low-Voltage Directive and will support all functions via software up-
date by the end of the transitional period.
The output control through the PSC required according to the German Renewa-
ble Energy Act can be realised via the optional CAN power control box.
Solar Inverter configuration The basic configuration of the NT Solar Inverter is shown in the block diagram.
The solar generator voltage connected to the inverter input is converted to al-
ternating current by the high-efficiency HERIC
®
inverter. A 5-core AC connec-
tion is used.
1.3 Integration into solar system
Solar generator configuration The technical data of the selected solar generator must match the Solar Inverter
specification (see Technical Data). Incorrect dimensioning can lead to reductions
in the yield and to destruction of the unit.
The Sundim design program from Sunways can be used for this purpose. Sun-
ways Sundim can be found on the enclosed CD-ROM or on our website at http:/
/www.sunways.eu/de/.
Be sure to take the following points into account before planning your system:
Watch the celestial alignment of the modules. In Central Europe a maximum
yield is achieved with a module tilt of 30° to the horizontal and direct south
orientation of the solar generator
field.
=
~
L1
L2
L3
PE
N
L1 L2 L3 PE N
+
DC+
DC
HERIC
® inverter
Solar generator 2
Control and monitoring
Solar generator 1
Solar generator 3
+
+
DC+
DC
DC+
DC
Grid