Operation
NT 10000...NT 12000 55
6.2 System monitoring
General information The basis for the system monitoring is the data logger integrated in the NT Solar
Inverter. The Solar Inverters of the NT series offer a wide range of monitoring
options for your solar system:
The Sunways browser can display instantaneous values, stored operating
data and settings.
With active alerting information about faults in the solar system can be sent
to a selected recipient via e-mail.
Via the Sunways Portal connection the NT Solar Inverter can send the opera-
ting data of your solar system to the Sunways Portal on a daily basis without
additional hardware. In this way you can monitor your yields via the Internet
from wherever you are.
Three networking options are available for access to the system monitoring
function:
Direct connection via an Ethernet cable (see section Direct Ethernet connec-
tion) or internal network (see section Connection via an existing Ethernet
network)
519:Time syn
(Warning)
Time synchronisation with the NTP server
has failed
Firewall port 123 is blocked.
Select an alternative time server
Remote access warnings
601:limit K2
(Warning)
The output power of your Solar Inverter is
limited to the threshold for relay K2
stored in the Sunways Browser, as speci-
fied by your power supply company.
Contact your energy supplier regar-
ding compensation depending on
the duration of the problem.
602:limit K3
(Warning)
The output power of your Solar Inverter is
limited to the threshold for relay K3
stored in the Sunways Browser, as speci-
fied by your power supply company.
Contact your energy supplier regarding
compensation depending on the durati-
on of the problem.
603:limit K4
(Warning)
The output power of your Solar Inverter is
limited to the threshold for relay K4
stored in the Sunways Browser, as speci-
fied by your power supply company.
Contact your energy supplier regarding
compensation depending on the durati-
on of the problem.
Service fault
9xx:Service A service error has occurred. Disconnect the Solar Inverter from
the grid and from the solar generator
and reconnect it.
If the error occurs again, please contact
the Technical Hotline. The phone number
is provided on the back of the manual.