Operation
56 NT 10000...NT 12000
NOTE
With a direct connection or an internal network without gateway to the Inter-
net the Solar Inverter is unable to send e-mails. Portal connection and active
alerting is therefore not possible.
Connection via Internet, e.g. via a DSL connection for the Solar Inverter (see
section Remote access via a DSL router)
Connection via a Sunways modem (see section Connection via a Sunways mo-
dem)
Integrated data logger The data logger integrated in the NT Solar Inverter stores the operating data of
your solar system. In addition to 5-minute mean values, energy yields are also
stored as 5-minute, daily, weekly, monthly and annual values. Up to 200 status
changes (warnings and errors with start and end ) are also stored. Each data re-
cord contains the data and time. The data logger is designed as a circulating me-
mory, i.e. the respective oldest data are overwritten with new data.
Operating data (5-min. ave-
rage values)
With this data memory volume approx. 30 days' worth of values can be stored
before the first value in the ring buffer is overwritten again.
Energy Yields
Status messages
Direct Ethernet connection The Solar Inverters are equipped with an Ethernet interface as standard for sys-
tem monitoring and configuration with a PC.
Number Value
4500 DC current
4500 DC voltage
4500 AC current
4500 AC voltage
4500 AC output
4500 Unit temperature
4500 Module irradiance (opt.)
4500 Module temperature (opt.)
Number Value
4500 5-minute yield
7300 Daily yield
250 Monthly yield
20 Annual yield
1 Total yield since commissioning
Number Value
200 Status changes