FAQ - TYPICAL ERRORS
ERROR: CAUSE/SOLUTION:
MACHINE DOESN’T START 1. Is it connected to the power supply?
2. Is there light in the display?
If not, please contact Swienty.
WEIGHT DOESN’T MATCH WITH WHAT THE
MACHINEDISPLAYS
1. Was the machine calibrated correctly? See page 15.
2. Repeat the calibration.
3. Is there air in the honey? See below.
4. Is the anti drip mounted the correct way? See page 23.
AIRINTHEHONEY 1.Istheproductinowoptimal?Seepage36.
2. Check if the hose is leakproof.
3. Check if the pump housing is tightened properly.
4. Check if the O-ring is mounted correctly in its track in
the pump housing.
5.CheckiftheO-ringintheinletandoutletttingare
intact.
6.Checkiftheinletttingistightened(seepage13,
point 10).
7. Lower the antidrip value (see page 11, antidrip func-
tion).
8. If there is still air in the honey after following all these
steps, please contact Swienty.
THE MACHINE “SPLASHES” SeeAIRINTHEHONEY.
MACHINE DOESN’T PUMP EVEN THOUGH
IT STARTS
1.Haveyoulledthepumphousingwithyourlling
substance?
2. Check if the pump direction is set correctly (with the
arrow’s direction).
DISPLAYDOESNOTCOUNTUPAFTERSTART 1. Reset the machine. See page 28.
The machine is set to its factory settings, as it was set
when you bought it. This means you need to set all
values you have changed again.
DISPLAYSHOWS“ENGINEOVERLOADED” 1.Thellingsubstanceistootoughandthespeedset
too high. Let the machine cool down and lower the
speed. If this doesn’t help, check for mechanical errors
in the pump housing. If this doesn’t solve the problem,
please contact Swienty.
DISPLAYSHOWS”ERRORPUMP” 1. Pump housing isn’t mounted correctly, see page 36
(Swienty logo may not be upside down).
2. Check if nuts are tightened.
HONEYDRIPSEVENTHOUGHANTIDRIP
IS ACTIVATED
1.Setawaitingtimebetweenllings.Oftenusedincon-
nectionwithaturntable.SetTIMEREADYtoe.g.1sec.
(seeparametersettingTIMEREADYpage27).
2. Wait a second before taking the jar off the table.
SUBSTANCE FOAMS TOO MUCH See speed program page 26.