EasyManua.ls Logo

SycoTec easyDrive 4624 - Page 16

SycoTec easyDrive 4624
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EN
16
Subindex 20
Subindex 20 refers to the 3rd Error (P32). It is a display value.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:20
stoerung_3
Variable
Unsigned16
ro
optional,
TPDO only
Subindex 21
Subindex 21 refers to the 4th Error (P33). It is a display value.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:21
stoerung_4
Variable
Unsigned16
ro
optional,
TPDO only
Subindex 22
Subindex 22 refers to the 5th Error (P34). It is a display value.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:22
stoerung_5
Variable
Unsigned16
ro
optional,
TPDO only
Subindex 24
Subindex 24 refers to the type of the Inverter (P36). It is a display value.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:24
t_Umrichter
Variable
Unsigned16
ro
optional,
TPDO only
Subindex 25
Subindex 25 refers to the Firmware (P37) of the inverter. It is a display value.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:25
rev_software
Variable
Unsigned16
ro
optional,
TPDO only
Subindex 27
Subindex 27 refers to the Serial number (P39) of the inverter. It is a display value.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:27
serialnummer
Variable
Unsigned16
ro
optional,
TPDO only
Subindex 29
Subindex 29 refers to the Minimum frequency (P41). The value is given in Hz.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:29
f_mot_min
Variable
Unsigned16
rw
no
Subindex 2a
Subindex 2a refers to the Maximum frequency (P42). The value is given in Hz.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:2a
f_mot_max
Variable
Unsigned16
rw
no

Table of Contents