EN
19
Subindex 42
Subindex 42 refers to the Voltage 3 (P66) of the V/Hz table.
The value is given from 1…650 in 0.1 V steps; 650 equals 65 V.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:42
U3
Variable
Unsigned16
rw
no
Subindex 46
Subindex 46 refers to the Speed control (P70).
Bit 3
Bit 2
Bit 1
Bit 0
Display inverter
0
0
0
0
No motor active
X
X
X
1
Pure speed control active (PMSM only)
X
X
1
X
V/Hz control active (DASM only)
X
1
X
X
I*R control active (DASM only)
1
X
X
X
Load compensation active (DASM only)
NOTE: See also Operating Manual Operating Software SycoDrive for HF Inverters e@syDrive 4624, 4625, 4626.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:46
Regler
Variable
Unsigned16
ro
no
Subindex 47
Subindex 47 refers to the I*R factor (P71) of the controller.
The value is given from 1…100 in 0.1 V/A steps; 100 equals 10 V/A.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:47
I*R-Faktor
Variable
Unsigned16
rw
no
Subindex 48
Subindex 48 refers to the Load comp. factor (P72) of the controller.
The value is given from 0…400 in 0.1 %/A~ steps; 400 equals 40 %/A~.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:48
Lastkompensation
Variable
Unsigned16
rw
no
Subindex 49
Subindex 49 refers to the Filter time (P73) of the I*R and Load compensation. The value is given in s.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:49
Komp-t_filt
Variable
Unsigned16
rw
no
Subindex 4b
Subindex 4b refers to the I²t threshold (P75). The value is given from 0…1000 in 0.1 % steps;
1000 equals 100 %.
Index
(hex)
Name
Object type
Data type
Access
PDO
mapping
Default
3000:4b
I2tThd
Variable
Unsigned16
rw
no