21
PROGRAMMING
Line1indicatesthebrewgroupandprogramassociatedwiththesengsbelow.
Line2showsthepercentofthetotalwatercountatwhichthemachinewillramptheshotpressuredown.
Loweredpressureneartheendoftheshotwillchangetheextraconrateandalter
theavoroftheshot.
Line3and4showthetotalwatercountassociatedwiththecurrentprogram.Asindicated,thereareabout
4.5‘counts’permilliliterdispensedbythemachine.Someofthisdispensedwaterisabsorbedandretained
bythecoeepuck,butgenerally,ifyouadd9counts,youshouldreceive2addionalmLofwater.
Tocycletothenextdisplayscreen,pressthedownbuon.
Line1showsthecurrentreadingofthesteamtanktemperatureprobe(250.7Finthisexample).Oncethis
temperaturereachesthesetpoint,thedigitaldisplaywillconnuouslycycleupanddownbysmallincre
mentsastheelectronicsbalancethetemperature.
Line2isindicangthesetpointof250.0F(121.1C).Theadjustablesetrangeforthesteamtankisbetween
200Fand265F(93.3Cand129.4C).
Line3and4areindicangthattheindependentloops1and2oftheheangelementareacve.
NOTE:Turningoffeitherloop1or2oftheelementcanbeusedasatroubleshoongprocedureandisnota
recommendedmethodofenergyconservaon.
Tocycletothenextdisplayscreen,pressthedownbuon.