50 Synopsys, Inc.
SolvNetPlus
DesignWare
5.60a
March 2020
Status LEDs PCIe IP Prototyping Kit Installation Guide
A.2 HAPS-80 Power-Up Sequence
During the power-up sequence, the supervision LEDs (RESET, READY, ALERT and PWR) change color.
After a successful power-up sequence, all LEDs must be green. The following list represents the color code
for the supervision LEDs.
Table A-2 indicates the different stages during the HAPS-80 power-up procedure and associated LED color
code.
Green Amber Red Unlit
Table A-2 HAPS-80 Power-up Supervision LEDs
LED
Power-up Procedure Action RESET READY ALERT PWR
Supervisor - Power On OK
ERROR Stop
Supervisor Design- Loaded OK
ERROR Stop
Supervisor Firmware - Check and Load OK
Error Stop
Power - Check OK
Error Stop
Slave Systems Version - Check OK
Error Stop
Startup Project - Load Yes
No Continue
Startup Project - Loaded Successfully Yes
Error Continue
Control Module – Power On OK
ERROR Stop